Aten-PE0212G 1U Desing, 12Ac Outlets Basic Pdu

Aten

Bu ürünü en uygun fiyata satın almak için teklif isteyebilirsiniz !



  • Ürün Açıklaması

<div id="features-tab" class="tab-content clearfix ui-tabs-panel ui-widget-content ui-corner-bottom tab-pane active"> <div class="col-sm-12 col-lg-12"> <p>&nbsp;</p> <ul> <li><span style="font-weight: 500; font-size: 17px; color: #017cc3; line-height: 2.1em;">Basic</span> <ul style="margin-left: -5px;"> <li>Space saving -1U rack mount design</li> <li>IEC or NEMA outlet models</li> <li>Overcurrent Protection</li> <li>Aluminum material</li> </ul> </li> </ul> <p><br /> &nbsp;</p> <ul> <li><span style="font-weight: 500; font-size: 17px; color: #017cc3; line-height: 2.1em;">Typical Applications</span> <ul style="margin-left: -5px;"> <li>Servers</li> <li>Network Devices</li> <li>Telecom Equipment</li> </ul> </li> </ul> <p>&nbsp;</p> <table class="spec_table" border="1"> <tbody> <tr> <td class="function">Function</td> <td class="modelname">PE0212A</td> <td class="modelname">PE0212B</td> <td class="modelname">PE0212G</td> </tr> <tr> <td class="title" colspan="4">Electrical</td> </tr> <tr> <td class="subtitle">Nominal Input Voltage</td> <td class="value">100-120 VAC</td> <td class="value">100-240 VAC</td> <td class="value">100-240 VAC</td> </tr> <tr> <td class="subtitle">Maximum Input Current</td> <td class="value">20A Max<br /> (UL de-rated 16A Max)</td> <td class="value">20A (Max)<br /> (UL de-rated 16A Max)</td> <td class="value">16A (Max)</td> </tr> <tr> <td class="subtitle">Input Frequency</td> <td class="value">50-60 Hz</td> <td class="value">50-60 Hz</td> <td class="value">50-60 Hz</td> </tr> <tr> <td class="subtitle">Input Connection</td> <td class="value">For A Plug NEMA L5-20P<br /> For A2 Plug : NEMA 5-20P</td> <td class="value">NEMA L6-20P</td> <td class="value">IEC-320 C20</td> </tr> <tr> <td class="subtitle">Input Power</td> <td class="value">2400VA(MAX);<br /> 1920VA(UL de-rated)</td> <td class="value">4800VA(Max);<br /> 3840VA(UL de-rated)</td> <td class="value">3840VA(Max)</td> </tr> <tr> <td class="subtitle">Outlet Type</td> <td class="value">(12) NEMA 5-20R</td> <td class="value">(12) IEC 320 C13</td> <td class="value">(12) IEC 320 C13</td> </tr> <tr> <td class="subtitle">Maximum Output Current (Outlet)</td> <td class="value">20A (Max)<br /> (UL de-rated 16A Max)</td> <td class="value">15A (Max)<br /> (UL de-rated 12A Max)</td> <td class="value">10A (Max)</td> </tr> <tr> <td class="subtitle">Maximum Output Current (Bank)</td> <td class="value">20A (Max)<br /> (UL de-rated 16A Max)</td> <td class="value">20A (Max)<br /> (UL de-rated 16A Max)</td> <td class="value">16A (Max)</td> </tr> <tr> <td class="subtitle">Maximum Output Current (Total)</td> <td class="value">20A (Max)<br /> (UL de-rated 16A Max)</td> <td class="value">20A (Max)<br /> (UL de-rated 16A Max)</td> <td class="value">16A (Max)</td> </tr> <tr> <td class="subtitle">OPD(Overcurrent Protection Device)</td> <td class="value">Yes</td> <td class="value">Yes</td> <td class="value">Yes</td> </tr> <tr> <td class="title" colspan="4">Physical Properties</td> </tr> <tr> <td class="subtitle">Dimensions (L x W x H)</td> <td class="value">48.80 x 4.40 x 4.50 cm<br /> (19.21 x 1.73 x 1.77 in.)</td> <td class="value">48.80 x 4.40 x 4.50 cm<br /> (19.21 x 1.73 x 1.77 in.)</td> <td class="value">48.80 x 4.40 x 4.50 cm<br /> (19.21 x 1.73 x 1.77 in.)</td> </tr> <tr> <td class="subtitle">Weight</td> <td class="value">0.88 kg ( 1.95 lb )</td> <td class="value">0.88 kg ( 1.95 lb )</td> <td class="value">0.88 kg ( 1.95 lb )</td> </tr> <tr> <td class="subtitle">Power Cord Length</td> <td class="value">10ft(12#)</td> <td class="value">10ft(12#)</td> <td class="value">10ft(3&times;1.5mm2)</td> </tr> <tr> <td class="title" colspan="4">Environmental</td> </tr> <tr> <td class="subtitle">Temperature (Operating / Storage)</td> <td class="value">0 &ndash; 40? / -20 &ndash; 60?<br /> *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.</td> <td class="value">0 &ndash; 40? / -20 &ndash; 60?<br /> *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.</td> <td class="value">0 &ndash; 40? / -20 &ndash; 60?<br /> *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations.</td> </tr> <tr> <td class="subtitle">Elevation (Operating / Storage)</td> <td class="value">3000m</td> <td class="value">3000m</td> <td class="value">3000m</td> </tr> <tr> <td class="title" colspan="4">Compliance</td> </tr> <tr> <td class="subtitle">EMC Verification</td> <td class="value">FCC Class A</td> <td class="value">FCC Class A</td> <td class="value">-</td> </tr> <tr> <td class="subtitle">Safety Verification</td> <td class="value">By Request</td> <td class="value">By Request</td> <td class="value">LVD</td> </tr> </tbody> </table> </div> </div> <p>&nbsp;</p>